Anesth Pain Med Search

CLOSE


Anesthetic Pharmacology
Anesthesia and Pain Medicine 2006;1(1):13-18.
Published online July 30, 2006.
The Comparison of Measured Hypnotic Levels among Propofol, Sevoflurane and Desflurane Anesthesia by Using EEG-entropy and Bispectral Index
Jin Deok Joo, Jin Whan Choi, Jang Hjeok In, Jin Woo Choi, Hae Jin Lee, Hong Soo Jung, Dae Woo Kim
Department of Anesthesiology and Pain Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea. VINCNT@chol.com
Abstract
BACKGROUND
Sevoflurane has been reported to associate with epileptiform activity during a rapidly increasing concentration, but desflurane isn't associated. This study was designed to compare the measured hypnotic levels by using EEG-entropy and bispectral index (BIS) among propofol target-controlled infusion (TCI), sevoflurane and desflurane anesthesia. METHODS: Sixty-five patients undergoing total hysterectomy were studied. Thirty patients were anesthetized with propofol TCI, twenty patients with sevoflurane, and fifteen patients with desflurane anesthesia. BIS, response entropy (RE), state entropy (SE), and hemodynamic variables were collected on the effect site concentrations of 1.5-10.0micro/ml for propofol TCI group. On the other hand, those data were collected on the end-tidal concentrations of 1.0-6.0 vol% for sevoflurane group and, 1.0-13.0 vol% for desflurane group. RESULTS: In propofol TCI group, there was a strong correlation between the measured hypnotic levels and the effect site concentrations of 1.5-10.0micro/ml. Furthermore, the measured values were significantly lower than previous corresponding values on 3.0-4.0 and 8.0micro/ml of the effect site concentrations. In sevoflurane group, the measured hypnotic levels increased paradoxically on the end-tidal concentration of 2.0-5.0 vol%. In desflurane group, the measured hypnotic levels showed ceiling effect in the concentration ranges of 3.0-12.0 vol%. CONCLUSIONS: The measured values by using EEG-entropy and BIS with propofol TCI were considered as useful indices of hypnotic level because of showing a strong correlation. However, those values didn't reflect real clinical hypnotic levels well partly with sevoflurane anesthesia because the measured hypnotic levels increased paradoxically. And it should be considered that those values showed ceiling effect from 3.0 vol% onward with desflurane anesthesia.
Key Words: bispectral index, desflurane, EEG-entropy, hypnotic level, propofol, sevoflurane
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,072 View
  • 13 Download
Related articles in Anesth Pain Med


ABOUT
ARTICLE & TOPICS
Article category

Browse all articles >

Topics

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: apm@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next